PosiTector® 200

Coating Thickness Gages for Non-Metal Substrates. Coating Thickness Gages for measuring on Concrete, Wood, Plastic, and more.

Non-destructively measures a wide variety of applications using proven ultrasound technology. Measure coating thickness over wood, concrete, plastic and more. Advanced models measure up to 3 layers with graphics.


Simple
Ready to measure — no calibration adjustment required for most applications
Enhanced one-handed menu navigation
Flashing display — ideal in a noisy environment
RESET feature instantly restores factory settings

Durable
Solvent, acid, oil, water and dust resistant - weatherproof
Shock-absorbing, protective rubber holster with belt clip
Two year warranty on gage body AND probe

Accurate
Certificate of Calibration showing traceability to NIST or PTB included (Long Form)
Responsive transducers provide fast, accurate readings
Proven non-destructive ultrasonic technique conforms to ASTM D6132 and ISO 2808

Versatile
High Contrast backlit display for bright or dark environments
Mils/Microns switchable
Selectable display languages
Flip display enables right-side-up viewing
Uses alkaline or rechargeable batteries (built-in charger)

Powerful
Statistics mode continually displays/updates average, standard deviation, min/max thickness and number of readings while measuring
Sealed USB port for fast, simple connection to a PC and to supply continuous power. USB cable included
Software Updates via web keep your gage current
Screen Capture – record and save image into USB flash memory for record keeping and review
Software Solutions for viewing, analyzing & reporting data
Every stored measurement is date and time stamped

Probe 200B
Typical Applications Polymer coatings on wood, plastic, etc.

Probe 200C
Typical Applications Coatings on concrete, fiberglass, etc

Probe 200D
Typical Applications Thick, soft coatings such as polyurea, asphalitic neoprene,
very thick polymers, etc.

Probes
200B
Typical Applications Polymer coatings on wood, plastic, etc.
Measurement Range* 13 – 1000 µm ; 0.5 – 40 mils
Accuracy +/– (2 µm + 3% of reading)
+/– (0.1mil + 3% of reading)
Minimum Layer 13 µm ; 0.5 mil
Thickness^

200C
Typical Applications Coatings on concrete, fiberglass, etc
Measurement Range* 50 – 3800 µm ; 2 –150 mils
Accuracy +/– (2 µm + 3% of reading)
+/– (0.1mil + 3% of reading)
Minimum Layer 50 µm ; 2 mils
Thickness^

200D
Typical Applications Thick, soft coatings such as polyurea, asphalitic neoprene,
very thick polymers, etc.
Measurement Range* 50 – 7600 µm ; 2 – 300 mils
Accuracy +/– (20 µm + 3% of reading)
+/– (1 mil + 3% of reading)
Minimum Layer 500 µm ; 20 mils
Thickness^

  • Range limits apply to polymer coatings. D probe– polyurea range is 50–5000 µm (2–200 mils).
    ^For multiple-layer applications only. Dependent on material being tested.