USN 60 / 60L: Portable Ultrasonic Flaw Detector

Waygate Technologies' USN 60 ultrasonic flaw detector series has been optimized for use in direct sunlight and operation at extreme temperatures.

These new characteristics make the instruments ideally suited for outdoor use with their increased long battery operation time. Depending on the applications challenges, you have the choice between the USN 60 and the USN 60L version.


Rugged USN durability
11 hours of battery operation
Fast rotary knob operation
Outstanding ultrasonic performance
Extreme temperature use (-20°C to +55°C /-4°F to 130°F)
Hi-resolution color LCD
4 selectable vibrant display color schemes to match lighting conditions
Gates and gate functions color coded for easy identification
Simple operation with fast rotary knob adjustments
Auto CAL makes calibration fast & easy
PRF (pulse repetition frequency) in spike mode: USN 60 = 15 Hz to 6 kHz; USN 60L = 15 Hz to 2 kHz
2 independent gates monitor amplitude and sound path distance for both flaw detection and thickness measurement applications
250 KHz to 25 MHz frequency range

A 6 kHz pulse repetition frequency, real-time analog and
TTL outputs makes the USN 60 flaw detectors series ideal for
a wide range of automated systems testing applications.
The exclusive SmartView feature displays even the shortest
echoes for critical scanning and rotating part inspections.

From rugged field inspections to
high resolution thin measurements, long acoustically clean
materials, and immersion systems, the USN 60 flaw detector
family extends the range of applications that a portable
instrument can perform. Furthermore the selectable 450V
Square Wave Pulser satisfies a wide range of tough-topenetrate applications,
such as difficult to penetrate metallic applications and especially non-metals inspection like
composite materials.

Range USN 60 ----- 0.040” to 1100” (1 mm to 28 m) at steel velocity; range
selectable in fixed steps or continuously variable
Range USN 60L ----- range is 0.040” to 480” (1 mm to 12 m)
Material velocity --- Continuously adjustable from 0.0394 to 0.6299
inches/µs (1000 to 16,000 m/s); 65 selectable material
velocities
Display delay ----- -20 to 3498 µs in steel (dependent on range)
Probe delay/zero ----- 0 to 999.9 µs
offset
Damping ----- 50, 75, 150, 500 ohms
Gain ----- 0 to 110 dB adjustable in selectable steps 0.1, 0.5, 1.0, 2.0,
6.0, user definable, and locked
Test modes ----- Pulse echo, dual, and thru-transmission
Pulser ----- Square wave excitation pulse
Pulse voltage ----- 50 to 450 V scrollable in 10 V adjustments
(Square wave pulser mode)

Pulse width (Square --- Tunable from 50 to 1000 ns in 10 ns adjustments
wave pulser mode)

Pulse energy ----- Low, high
(Spike mode)

Pulse repetition ----- Autolow, autohigh, manually adjustable from 15 to 6000
frequency USN 60 Hz (spike mode) and 15 to 2000 Hz in square wave mode,
in 5 Hz increments, external trigger (spike mode only)

Pulse repetition ----- Limited to 2000 Hz in both spike and
frequency USN 60 square wave mode

Bandwidth ----- 0.25 to 25 MHz with 10 selectable settings including
(amplifier bandpass) broadband

Gate monitors ----- Two independent flaw gates controllable over entire
sweep range
Measurement modes ----- Zero-to-first, multi-echo with selectable flank or peak
detection
Rectification ----- Positive halfwave, negative halfwave, fullwave, RF
Reject (suppression) -- 0 to 80% linear
Units ----- Inch, millimeter, or microsecond selectable

Operating ----- -20° to 55°C (-4° to 130°F);
temperature -25° to 70ºC (-13° to 158 º F ) storable

*download brochure for more information